BOULDERLINK MESSAGES
Each component in the system can send a message to the 2010 which
is then shown on the display. This is particularly helpful in confirming
the operating status of each power amplifier in a multiple amplifier
system.
“AMP 1 ERROR” means that an internal power supply has failed and
amplifier #1 has turned itself off to protect the speakers from damage.
“AMP 1 DC” means that amplifier #1 has turned itself off due to a
DC offset voltage being detected at its inputs.
“AMP 1 HOT” means that amplifier #1 has turned itself off due to a
higher than normal temperature condition on the heatsinks.
“AMP CLIP” means that the amplifier’s output has momentarily
reached its output voltage limitation.